Duraline Highway Lighting Systems AASHTO Compliant he Field Proven Wiring
System within the Many Department’s of Transportation Since 1992
|
|
Plug us in
for Safety
AASHTO Compliant
The Field Proven Wiring System within
the Many Department’s of Transportation Since 1992
|
|
/ [MG]²
Patented
Roadway Lighting
Break-Away Systems
IP-68 Rated
FL
and AL Highway Lighting Systems
FL and AL Highway
Lighting systems are Factory Mutual Approved for IP68.
The IP68 rating provides complete protection from the ingress of
dust and allows
for continuous immersion in 6' of water when the connectors and
receptacles are capped or mated.
 |
|
|
|

|
FL
Lighting Systems
****NOW IP-68 RATED****
The FL Lighting System is designed so that when a pole is accidentally
knocked down, the pole cable will disconnect leaving a 2" to
3" of cable and a disconnected female plug (intrinsically safe)
above ground. This system eliminates damage to cable systems in the
downed pole or in adjacent poles. Competitor's roadway systems utilize
breakaway fuse holders, which are crimped onto the cable. This type
of arrangement is known to cause damage to the cable systems of not
only the damaged pole, but also adjacent poles. A pole that has been
knocked down in an accident leaves live, exposed wires above ground.
These wires can easily spark a fire or electrocute accident victims,
rescue workers or repairmen. Rework of two or more poles is generally
required to repair the system. The distinguishing feature of the FL
system is that the surge Arrestor is positioned after the fuses in
the fused distribution cable assembly, on the load side of the circuit.

|
| |
|
|

|
AL
Lighting Systems
****NOW IP-68 RATED****
The AL system is designed so that when a pole is accidentally knocked
down, the pole cable will disconnect leaving a 2" to 3"
of cable and a disconnected female plug (intrinsically safe) above
ground. This system eliminates damage to cable systems in the downed
pole or in adjacent poles. Competitor's Roadway systems utilize breakaway
fuse holders, which are crimped onto the cable. This type of arrangement
is known to cause damage to the cable systems of not only the damaged
pole, but also adjacent poles. A pole that has been knocked down in
an accident leaves live, exposed wires above ground. These wires can
easily spark a fire or electrocute accident victims, rescue workers
or repairmen. Rework of two or more poles is generally required to
repair the system. The distinguishing feature of the AL system is that
the surge Arrestor is positioned before the fuses in the fused cable
assembly, on the line side of the circuit.

|
| |
|
|
| |